10 03/2015 11 WR Principles of design Load-bearing capacity values WR-T ETA-12/0062 lef = actual thread length in structural component hmin = minimum height of structural component – Values apply to connections where half of each fastener is in each structural component. – Connection geometry as shown in the drawings must be complied with. – Calculation of design values as shown in the box to the left of the tables. – All calculations must be verified and signed off by the planner in charge before the work is performed. Remarks 2/6 Pull-out resistance from 45° to 90° in dependancy of wood density Table 2 α = 45°- 90° α = 45°- 90° Gross density k [kg/m3] 350 380 410 430 450 WR-T-9xL[mm] 250 lef [mm] 125 Pull-out resistance from timber F1,Rk [kN] 14,4 15,4 16,3 17,0 17,6 300 150 17,3 18,5 19,6 20,4 21,1 350 175 20,2 21,5 22,9 23,8 24,6 400 200 23,0 24,6 26,1 27,2 28,2 450 225 25,9 27,7 29,4 30,6 31,7 500 250 28,8 30,8 32,7 34,0 35,2 Tensile failure of fastener F2,Rk [kN] 35,9 Gross density k [kg/m3] 350 380 410 430 450 WR-T-13xL[mm] 400 lef [mm] 200 Pull-out resistance from timber F1,Rk [kN] 33,5 35,8 38,1 39,5 41,0 500 250 41,9 44,8 47,6 49,4 51,3 600 300 50,3 53,7 57,1 59,3 61,5 700 350 58,7 62,7 66,6 69,2 71,8 800 400 67,1 71,6 76,1 79,1 82,0 900 450 75,5 80,6 85,6 89,0 92,3 1000 500 83,9 89,6 95,2 98,9 102,5 Tensile failure of fastener F2,Rk [kN] 58,4 Gross density k [kg/m3] 350 380 410 430 450 WR-T-9xL[mm] 250 lef [mm] 125 hmin [mm] 95 Pull-out resistance from timber F1,Rk [kN] 10,2 10,9 11,6 12,0 12,4 300 150 113 12,2 13,0 13,9 14,4 14,9 350 175 131 14,3 15,2 16,2 16,8 17,4 400 200 148 16,3 17,4 18,5 19,2 19,9 450 225 166 18,3 19,6 20,8 21,6 22,4 500 250 184 20,4 21,7 23,1 24,0 24,9 Tensile failure of fastener F2,Rk [kN] 25,4 Shearing connection, half thread length per structural component Table 3 Gross density k [kg/m3] 350 380 410 430 450 WR-T-13xL[mm] 400 lef [mm] 200 hmin [mm] 152 Pull-out resistance from timber F1,Rk [kN] 23,7 25,3 26,9 28,0 29,0 500 250 188 29,6 31,7 33,6 35,0 36,2 600 300 223 35,6 38,0 40,4 41,9 43,5 700 350 258 41,5 44,3 47,1 48,9 50,7 800 400 294 47,4 50,7 53,8 55,9 58,0 900 450 329 53,4 57,0 60,6 62,9 65,2 1000 500 365 59,3 63,3 67,3 69,9 72,5 Tensile failure of fastener F2,Rk [kN] 41,3 NB: if fasteners are inser- ted at an angle from one side, forces can only be absorbed from one side (cf. sketch) Calculation values for the characteristic bulk density values Table 1 Solid timber, cross-laminated timber C 24 30 Glulam timber GL 24c 28c / 24h 32c / 28h 36c / 32h 36h Gross density k [kg/m3] 350 380 410 430 450 l M1 =1,3 M2 =1,3 F1,Rk . kmod M1 F2,Rk M2 FN,Rd=min ( ) M1 (GL)=1,25 M1 =1,3 M2 =1,3 F1,Rk . kmod M1 F2,Rk M2 Fv,Rd =min ( ) M1 (GL)=1,25 11. Technical documentation and data sheets 1003/2015 Gross density k [kg/m3] 350380410430450 14,415,416,317,017,6 30015017,318,519,620,421,1 35017520,221,522,923,824,6 40020023,024,626,127,228,2 45022525,927,729,430,631,7 50025028,830,832,734,035,2 Gross density k [kg/m3] 350380410430450 33,535,838,139,541,0 50025041,944,847,649,451,3 60030050,353,757,159,361,5 70035058,762,766,669,271,8 80040067,171,676,179,182,0 90045075,580,685,689,092,3 100050083,989,695,298,9102,5 Gross density k [kg/m3] 350380410430450 10,210,911,612,012,4 30015011312,213,013,914,414,9 35017513114,315,216,216,817,4 40020014816,317,418,519,219,9 45022516618,319,620,821,622,4 50025018420,421,723,124,024,9 Gross density k [kg/m3] 350380410430450 23,725,326,928,029,0 50025018829,631,733,635,036,2 60030022335,638,040,441,943,5 70035025841,544,347,148,950,7 80040029447,450,753,855,958,0 90045032953,457,060,662,965,2 100050036559,363,367,369,972,5 Solid timber, cross-laminated timber C 2430 Gross density k [kg/m3] 350380410430450

Pages Overview