| Pilot drilling in the HPL panel with the 6 mm dia. HSS blind hole drill with depth stop (hole diameter 5,95 - 6,1 mm). Minimum residual thickness 1,5 mm. | Position the pre-drilled bracket over the hole in the panel and push through the TU-S blind fastener. | Remove the mandrel completely with the riveting tool (e.g. SFS TPR50 or PowerBird®, use nosepiece 17/36 or 17/40). |